Setting up USB Gateways

  • Updated

This article is written for: Zello Work Zello Friends & Family.

This article provides step-by-step instructions on setting up a USB gateway for Zello Work. To configure your gateway with Zello Work, you will need to download the Legacy PC desktop app, as well as any Drivers needed for your USB gateway. Additionally, you will need to create an account for the gateway from your management console, which will be used to sign in to the Zello Work app. 

Please note that you may require administrator permissions in order to follow the below instructions. Installation of the Zello Work application and/or any drivers may require assistance from your internal IT support.

Part One: Add a Gateway from within your management console

1. Log into your management console ([Your network name].zellowork.com) with your admin account.  

2. From the top navigation bar, select +New New Gateway.
Screenshot 2024-06-03 at 12.17.48 PM.png

3. Assign a username, password, display name, and tags (if applicable) to your gateway, then click Create Gateway. We recommend securely storing these credentials, as they'll be needed to sign in to the PC app at a later step. 
Screenshot 2024-06-03 at 12.39.21 PM.png

4. To access your gateway's user profile and assign it to a channel, go to Menu > Gateways.
Screenshot 2024-06-03 at 12.49.20 PM.png

5. From the Gateways page. select the gateway you've just created. Then, click the + at the top-right corner of the Channels box, and select the channel you'd like to assign the gateway.

Gateway (3) (1).png

Note: A gateway is only capable of connecting to one channel at a time. 

Part Two: Install the Zello Work PC app

1. If the Zello Work PC app is not yet installed, follow steps 2 - 4 to install the app. If it is already installed, skip to part three below. 

2. Go to the homepage of the management console. From the home screen, click “release archives” under Service Status and Updates:
signed-url-redirect-1.png

3. Scroll down on this page to the “Legacy PC App” and download the current release version, as denoted by the green box which says “current."

4. Once downloaded, run the .exe file in order to install the Zello Work application. 

Part Three: Set Up the Gateway

1. Download the any required drivers that were provided by the gateway hardware vendor. If you don't have one, please reach out to the vendor. 

2. Make sure that the gateway is connected to the PC, and that you have a radio connected to the gateway.

3. Login into the Zello Work app using the username and password that you assigned to your gateway in Part 1, step 3 of this article.

When logged in you should see a status screen like the one below. If you don't see this screen, verify that your log-on information is for a gateway and not a user:
gateway status screen.png

Note: TX denotes Zello Work to radio connection, and RX denotes the connection from the radio to Zello Work. VOX mode is used by default in both directions.

7. Open the Gateway settings by selecting Tools, then Options.
tools_ options legacy pc.png
8. Under the Audio tab,  make sure that the ‘Playback device’ is outputting to the gateway and that the ‘Recording device’ is inputting from the gateway, which should be labelled as “USB PnP sound device”:
playback_recording device.png

Note: Depending on your installation of the drivers, the correct option(s) for the playback or recording device may be labeled differently than shown above.

9. Under the Radio tab, Select the COM port under TX to control the PTT of your radio. Choose the port, where the gateway is connected as well as RTS or DTR signal and low or high active level. Use the default VOX mode options for RX.
radio - com port.png

Note: Wake up sequence length allows you to set the length of a tone that is sent to your radio before the actual transmission, which triggers the VOX circuit and eliminates the loss of the beginning of transmissions.

 Tip: Your gateway may be assigned to a different COM than the ones shown in these examples. If you are not allowed to select COM-port, open your device manager in Windows and make sure that the driver is properly installed. In some cases, Windows will find this driver once you have installed it before:
devicemanager.png

10. Make sure VOX mode is enabled.
vox mode.png

  • Activation threshold is the sound level of the signal from the radio above which transmission starts.
  • De-activation threshold is the sound level below which transmission stops. It cannot be set higher than the activation threshold, and it's best to have it set to ~5dB lower.
  • Trigger time is the amount of time VOX takes to trigger transmission. Increasing it will help eliminate false transmissions caused by short impulses.
  • Relaxation time is the amount of time VOX takes to turn off. Increase it to allow longer pauses in transmissions.

11. Click OK to close settings and apply your new configuration.



You can now test your gateway with other Zello users. Please ensure that both your gateway and users are in the channel you're using to test.

  • If configuring multiple gateways, please refer to this article to ensure proper configuration. 
  • If configuring JPS Interoperability Gateways, please refer to this article

Tip: Tweak audio settings to improve audio quality here.